Unified Facilities Criteria (UFC) Continuous Child Care Facilities
Programs:
24/7 Centers
Resource Type:
General
Published:
04/14
Unified Facilities Criteria (UFC 4-740-15) Continuous Child Care Facilities policy - used in reference to 24/7 centers
Table of Contents
- CHAPTER 1 INTRODUCTION
- 1-1 SCOPE OF DOCUMENT.
- 1-2 SCOPE OF FACILITY.
- TABLE 1-1. CCCF FUNCTIONAL PROGRAM AREAS
- 1-3 USERS OF FACILITY.
- 1-4 PROGRAM AUTHORITIES.
- CHAPTER 2 PLANNING AND LAYOUT
- 2-1 SIZE DETERMINANTS.
- 2-2 SPACE PROGRAM.
- 2-3 LOCATION DETERMINANTS.
- 2-3.1 Site Size.
- 2-3.2 Function.
- 2-3.3 Safety.
- 2-3.4 Natural Environment.
- 2-3.5 Combined Facilities.
- 2-4 LAYOUT AND ADJACENCIES.
- FIGURE 2-1. CCCF BUBBLE DIAGRAM
- CHAPTER 3 GENERAL DESIGN CRITERIA
- 3-1 GENERAL.
- 3-2 ACCESSIBILITY.
- 3-3 CHILD ABUSE PREVENTION.
- 3-3.1 Building Perimeter.
- 3-4 ARCHITECTURE.
- 3-4.1 Stories.
- 3-4.2 Exterior Design.
- 3-4.2.1 Entrance.
- 3-4.2.2 Roof.
- 3-4.2.3 Windows and Doors.
- 3-4.3 Interior Design.
- 3-4.3.1 Interior Doors and Windows.
- 3-4.3.1.1 Interior Glass.
- 3-4.3.1.2 Interior Doors.
- 3-4.3.2 Window Treatments.
- 3-4.3.3 Counters, Casework, and Cabinets.
- 3-4.3.4 Other Interior Construction.
- 3-4.3.5 Finishes.
- 3-4.3.5.1 General.
- 3-4.3.5.2 Soft Floor Coverings.
- 3-4.3.5.3 Resilient Floor Coverings.
- 3-4.4 Acoustics.
- 3-4.4.1 Exterior Acoustics.
- 3-4.4.1.1 Noise Levels.
- 3-4.4.1.2 Acoustical Criteria.
- 3-4.4.2 Interior Acoustics.
- 3-5 PLUMBING.
- 3-6 MECHANICAL.
- 3-7 FIRE PROTECTION AND LIFE SAFETY.
- 3-7.1 Use and Occupancy Classification.
- 3-7.2 Exit Requirements.
- 3-7.3 Emergency Lighting.
- 3-7.4 Fire Separation.
- 3-7.5 Fire Suppression Systems.
- 3-7.6 Fire Detection and Alarm System.
- 3-7.7 Carbon Monoxide Detection.
- 3-7.8 Conversions.
- 3-8 ELECTRICAL.
- 3-8.1 Lighting.
- 3-8.2 CCTV.
- 3-9 FURNISHINGS.
- 3-10 SITE WORK.
- 3-10.1 Landscaping.
- 3-10.2 Site Circulation and Parking.
- 3-10.3 Site Plumbing.
- 3-10.4 Site Lighting and CCTV.
- CHAPTER 4 SPECIFIC DESIGN CRITERIA
- 4-1 INTRODUCTION.
- 4-2 BUILDING DESIGN CRITERIA.
- TABLE 4-1. FOYER
- TABLE 4-2. LIVING ROOM
- TABLE 4-3. PLAY ROOM
- TABLE 4-4. DINING ROOM
- TABLE 4-5. KITCHEN
- TABLE 4-6. STAFF DESK AREA
- TABLE 4-7. CRIB/INFANT ROOM
- TABLE 4-8. BEDROOMS
- TABLE 4-9. OPTION A TOILETS
- TABLE 4-10. OPTION B TOILETS
- TABLE 4-11. STAFF TOILET
- TABLE 4-12. LAUNDRY
- TABLE 4-13. INTERIOR STORAGE
- TABLE 4-14. STAFF DEN/OFFICE
- TABLE 4-15. STAFF STORAGE
- TABLE 4-16. OUTDOOR STORAGE
- 4-3 OUTDOOR ACTIVITY AREA DESIGN CRITERIA.
- 4-3.1 General.
- 4-3.2 Layout.
- 4-3.3 Fencing.
- 4-3.4 Play Equipment.
- 4-3.4.1 Industry Standards.
- 4-3.4.2 Additional DoD Standards.
- 4-3.4.2.1 Selection Criteria.
- 4-3.4.2.2 Installation Criteria.
- 4-3.4.2.3 Exclusions.
- 4-3.4.2.4 Exceptions and Modifications.
- 4-3.5 Surfaces.
- 4-3.5.1 Use Zones.
- 4-3.5.2 Wheeled Toy Pathways.
- 4-3.5.3 General.
- APPENDIX A REFERENCES
- APPENDIX B SPACE PLANNING
- B-1 OPTION A FACILITY SAMPLE SPREADSHEET.
- FIGURE B-1. SAMPLE OPTION A FACILITY CCCF SPACE PROGRAM
- B-2 OPTION B FACILITY SAMPLE SPREADSHEET.
- FIGURE B-2. SAMPLE OPTION B FACILITY CCCF SPACE PROGRAM
- APPENDIX C POISONOUS AND NON-POISONOUS PLANTS
- TABLE C-1. COMMON POISONOUS PLANTS
- TABLE C-2. COMMON NON-POISONOUS PLANTS